Cooling incubatorsCooled incubators with compressor cooling ICP
9.538 017 LLG WWW-Catalog

9.538 017

Cooled incubators with compressor cooling ICP

The cooled incubators with the unique ControlCOCKPIT for a quick and intuitive operation. Ideal at temperatures around zero and below. For rapid and precise alternation between heating up and cooling down times in ramp operation. Extraordinarily quiet.

Standard equipment :
  • PID microprocessor control with integrated auto-diagnostic system
  • Interior stainless steel, material 1.4301 (ASTM 304) very stable and easy to clean
  • Structured stainless steel housing, scratch-resistant, robust and durable; rear of zinc-plated steel (all sizes mounted on lockable castors)
  • High-temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standards
  • Internal data logger with a storage capacity of at least 10 years
  • German, English, French, Spanish, Polish, Czech, Hungarian language settings available on the ControlCOCKPIT
  • Digital backwards counter with target time setting adjustable between 1 minute and 99 days
  • The SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamber.
  • Adjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT

TwinDISPLAY: ControlCOCKPIT with two TFT colour displays
  • Available parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), fan speed, exhaust air flap position, programme time, time zones, summertime/wintertime
  • Two Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error
  • AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port
  • ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function
  • Displaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week)
  • Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online logging
  • Multiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2) and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over/undertemperature alarm
(W x D x H)
(W x D x H)
PKCat. No.
ICP5553585 x 514** x 1153400 x 330* x 4004/18919.538 013
ICP55 (UK)53585 x 514** x 1153400 x 330* x 4004/18916.283 473
ICP110108745 x 584** x 1233560 x 400* x 4805/211319.538 014
ICP110 (UK)108745 x 584** x 1233560 x 400* x 4805/211316.263 156
ICP260256824 x 684** x 1552640 x 500* x 8009/215719.538 015
ICP4504491224 x 784** x 16131040 x 600* x 7208/221719.538 016
ICP7507491224 x 784** x 19501040 x 600* x 120014/224919.538 017
* Minus 33 mm for fan
** Depth without door handle, please add 56 mm