InformationDetailsAlternatives/Accessories
 
Photometers AL100 Boiler Water, Cooling Water


Photometers AL100 Boiler Water, Cooling Water

Photometers AL100 Boiler Water, Cooling Water

Photometer instruments, specially designed for cooling and boiler water analysis. Thanks to the handy format and the user-friendly indicator chemistry, most of the important parameters can be determined on site. The photometers are supplied pre-calibrated with test methods, simply add the appropriate AQUALYTIC® reagent sets (tablets, powder packs and liquids).
  • Scroll Memory
  • Automatic Switch-Off
  • Real-Time-Clock and Date
  • Calibration Mode
  • Backlit Display
  • Storage Function
  • One Time Zero (OTZ)
  • Waterproof (IP 68)

Scope of supply: instrument AL100 in a sturdy plastic case, batteries, 3 glass vials, standard accessories, instruction manual.
Please order reagents separately! Please pay attention that some reagents could be used for Boiler Water or Cooling Water only.
OpticsLEDs, interference filters (IF) and photo sensor in transparent sample chamber
Wavelength Accuracy± 1 nm
Photometric Accuracy
Photometric Resolution
3% FS (T = 20°C - 25°C)
0,01 A
Power Supply4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests
Auto-Offautomatic switch-off
Displaybacklit LCD (on keypress)
Storageinternal ring memory for 16 data sets
Interfacesinfrared interface for test data transfer
Additional Featurereal time clock and date
Calibrationfactory calibration and user calibration. Reset to factory calibration possible
Dimensions155 x 75 x 35 mm (L x W x H)
Weightbasic unit approx. 260 g
Environmental conditionstemperature: 5 - 40 °C, rel. humidity: 30 -90% (non condensing)
 
Data
Bestell Nr.
GHS
Signalwort
H-Satz
P-Satz
UN/Nr.
Bestell Nr.
6.257 410
GHS
Signalwort
Danger
H-Satz
H290 | H314
P-Satz
P260 | P280 | P301+P330+P331 | P303+P361+P353 | P305+P351+P338 | P310
UN/Nr.
2031
Bestell Nr.
6.232 946
GHS
Signalwort
Warning
H-Satz
H317
P-Satz
P261 | P280 | P302+P352 | P363 | P333+P313
UN/Nr.
Bestell Nr.
9.699 332
GHS
Signalwort
Danger
H-Satz
H290 | H314
P-Satz
P301+P330+P331 | P303+P361+P353 | P304+P340 | P305+P351+P338 | P310 | P405
UN/Nr.
 DescriptionForPackage
contents
PKCat. No. 
 AL 100 Boiler  19.699 278
 AL 100 Cooling  19.699 279
 Reagent Set DEHA (20 - 500 μg/l DEHA)Boiler waterset for 100 tests16.257 410
 Reagent Set Copper (0,3 - 5,0 mg/l Cu) combi pack no.1/2, each 100 tabl.2006.232 946
 Reagent Set Oxygen (10 - 800 μg/l O2)Boiler waterliquid reagent of 30 vials16.229 104
 Reagent Set Chlorine (0,01 - 6,0 mg/l Cl2) and (5 - 200 mg/l Cl2)Cooling watercombi pack, each 100 tabl.1006.230 324
 Reagent Set Chloride (0,5 - 20 mg/l Cl-)Boiler waterliquid reagent of 65ml19.699 330
 Reagent Set Iron (0,03 - 2,00 mg/l Fe2+/3+) liquid reagent of 65ml19.699 331
 Reagent Set Phosphate (5 - 80 mg/l PO4)Boiler waterliquid reagent of 65ml19.699 332
 Reagent Set Polyacrylate (1 - 30 mg/l) liquid reagent of 65ml19.699 333
 Reagent Set Zinc (0,1 - 2,5 mg/l Zn)Cooling waterliquid reagent of 65ml19.699 334

last visited